Event Users

Each event user must be configured to select the event channel to listen to. An event user may require the event signal to be either synchronous or asynchronous to the system clock. An asynchronous event user can respond to events in sleep modes when clocks are not running. Such events can also be responded to outside the normal edges of the (prescaled) clocks in the system, making the event user respond faster than the clock frequency would suggest. For details on the requirements of each peripheral, refer to the documentation of the corresponding peripheral.

User Module/Event Mode Input Format Asynchronous
TCAn CNT_POSEDGE Edge No
CNT_ANYEDGE Edge No
CNT_HIGHLVL Level No
UPDOWN Level No
TCBn Time-out check Edge No
Input Capture on Event Edge No
Input Capture Frequency Measurement Edge No
Input Capture Pulse-Width Measurement Edge No
Input Capture Frequency and Pulse Width Measurement Edge No
Single-Shot Edge Yes
USARTn IrDA Mode Level No
CCLLUTnx LUTn input x or clock signal Level Yes
ADCn ADC start on event Edge Yes
EVOUTx Forward event signal to pin Level Yes