Software Trigger
Name:
SWTRIG
Offset:
0x0C
Reset:
0x00
Access:
Write-Protected, Write-Synchronized
Bit76543210
STARTFLUSH
AccessR/WR/W
Reset00

Bit 1 – START: ADC Start Conversion

ADC Start Conversion

Writing this bit to zero will have no effect.

ValueDescription
0

The ADC will not start a conversion.

1

The ADC will start a conversion. The bit is cleared by hardware when the conversion has started. Setting this bit when it is already set has no effect.

Bit 0 – FLUSH: ADC Conversion Flush

ADC Conversion Flush

After the flush, the ADC will resume where it left off; i.e., if a conversion was pending, the ADC will start a new conversion.

Writing this bit to zero will have no effect.

ValueDescription
0

No flush action.

1

"Writing a '1' to this bit will flush the ADC pipeline. A flush will restart the ADC clock on the next peripheral clock edge, and all conversions in progress will be aborted and lost. This bit will be cleared after the ADC has been flushed.

After the flush, the ADC will resume where it left off; i.e., if a conversion was pending, the ADC will start a new conversion.