General Operating Ratings

The device must operate within the ratings in order for all other electrical characteristics and typical characteristics of the device to be valid.

Table 1. General Operating Conditions
Symbol Parameter Condition Min. Typ. Max. Units
VDD Power supply voltage   1.62(1) 3.3 3.63 V
VDDANA Analog supply voltage   1.62(1) 3.3 3.63 V
TA Temperature range   -40 25 85 °C
TJ Junction temperature   - - 100 °C
  1. With BOD33 disabled. If the BOD33 is enabled, check Table 1.