ADCP

ADC Charge Pump Control Register
Name:
ADCP
Address:
0x3D8
Reset:
Access:
Bit76543210
CPONCPRDY
AccessR/WR
Reset00

Bit 7 – CPON: Charge Pump On Control

Charge Pump On Control

ValueDescription
1 Charge Pump On when requested by the ADC
0 Charge Pump Off

Bit 0 – CPRDY: Charge Pump Ready Status

Charge Pump Ready Status

ValueDescription
1 Charge Pump is ready