ADSTAT
'b100.‘b100
appears between the two triggers when DSEN = 1 and CONT =
0.| Bit7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| AOV | UTHR | LTHR | MATH | STAT[2:0] | |||
| AccessR/C/HS/HC | R | R | R/C/HS | R | R | R | |
| Reset0 | 0 | 0 | 0 | 0 | 0 | 0 | |
ADC Accumulator Overflow
| Value | Description |
|---|---|
| 1 | ADACC or ADFLTR or ADERR registers have overflowed |
| 0 | ADACC, ADFLTR and ADERR registers have not overflowed |
ADC Module Greater-than Upper Threshold Flag
| Value | Description |
|---|---|
| 1 | ADERR > ADUTH |
| 0 | ADERR≤ADUTH |
ADC Module Less-than Lower Threshold Flag
| Value | Description |
|---|---|
| 1 | ADERR< ADLTH |
| 0 | ADERR≥ADLTH |
ADC Module Computation Status
ADC Module Computation Status(1)
| Value | Description |
|---|---|
| 1 | Registers ADACC, ADFLTR, ADUTH, ADLTH and the AOV bit are updating or have already updated |
| 0 | Associated registers/bits have not changed since this bit was last cleared |
ADC Module Cycle Multi-Stage Status
| Value | Description |
|---|---|
| 111 | ADC module is in 2nd conversion stage |
| 110 | ADC module is in 2nd acquisition stage |
| 101 | ADC module is in 2nd precharge stage |
| 100 | ADC computation is suspended between 1st and 2nd sample; the computation results are incomplete and awaiting data from the 2nd sample(2,3) |
| 011 | ADC module is in 1st conversion stage |
| 010 | ADC module is in 1st acquisition stage |
| 001 | ADC module is in 1st precharge stage |
| 000 | ADC module is not converting |