Silicon Issue Summary

Legend
-
Erratum is not applicable.
X
Erratum is applicable.
*
This silicon revision was never released to production.
Peripheral Short Description Valid for Silicon Revision
Rev. A Rev. B
Device The Temperature Sensor is Not Calibrated on Parts with Date Code 727, 728 and 1728 (Year 2017, Week 27/28) - X
AC AC Interrupt Flag Not Set Unless Interrupt is Enabled X -
False Triggers May Occur Under Certain Conditions X -
ADC One Extra Measurement Performed After Disabling ADC Free-Running Mode X X
Changing ADC Control Bits During Free-Running Mode not Working X -
ADC Wake-Up with WCOMP X -
SAMPDLY and ASDV Does Not Work Together With SAMPLEN X -
ADC Functionality Cannot be Ensured with CLKADC Above 1.5 MHz and a Setting of 25% Duty Cycle X X
ADC Performance Degrades with CLKADC Above 1.5 MHz and VDD < 2.7V X X
CCL Connecting LUTs in Linked Mode Require OUTEN Set to ‘1’ X X
D-latch is Not Functional X X
RTC Any Write to the RTC.CTRLA Register Resets the RTC and PIT Prescaler X X
Disabling the RTC Stops the PIT X X
TCB Minimum Event Duration Must Exceed the Selected Clock Period X X
The TCB Interrupt Flag is Cleared When Reading CCMPH X -
TCB Input Capture Frequency and Pulse-Width Measurement Mode Not Working with Prescaled Clock X -
The TCA Restart Command Does Not Force a Restart of TCB X X
TWI TIMEOUT Bits in the TWI.MCTRLB Register are Not Accessible X -
TWI Smart Mode Gives Extra Clock Pulse X -
TWI Master Mode Wrongly Detects the Start Bit as a Stop Bit X -
The TWI Master Enable Quick Command is Not Accessible X -
USART TXD Pin Override Not Released When Disabling the Transmitter X X
Frame Error on a Previous Message May Cause False Start Bit Detection X X