Lumped Sensor

A Lumped sensor is implemented as a combination of multiple sense lines (self-capacitance measurement) or multiple drive and sense lines (mutual capacitance measurement) to act as one single sensor. This provides the application developer with greater flexibility in the touch sensor implementation.

Touch detection on a lumped sensor is implemented in the same way as a single node touch button. The capacitance of the lump sensor is equal to or more than the sum of the individual sensors’ capacitance. Lumping too many sensor may result in saturation. In general, the capacitance of the self-capacitance sensor is higher than the mutual capacitance sensor. The number of sensor electrodes that can be lumped is relatively less for self-capacitance designs.