This register is
write-restricted and only writable if bit fields CCCR.CCE = 1 and CCCR.INIT =
1.
Accept Non-matching Frames Standard
Defines how received messages with 11-bit IDs that do not match any element
of the filter list are treated.
| Value | Name | Description |
|---|
| 0x0 |
RXF0 |
Accept in Rx FIFO 0. |
| 0x1 |
RXF1 |
Accept in Rx FIFO 1. |
| 0x2 or 0x3 |
REJECT |
Reject |
Accept Non-matching Frames Extended
Defines how received messages with 29-bit IDs that do not match any element
of the filter list are treated.
| Value | Name | Description |
|---|
| 0x0 |
RXF0 |
Accept in Rx FIFO 0. |
| 0x1 |
RXF1 |
Accept in Rx FIFO 1. |
| 0x2 or 0x3 |
REJECT |
Reject |
Reject Remote Frames Standard
| Value | Description |
|---|
| 0 |
Filter remote frames with 11-bit standard
IDs. |
| 1 |
Reject all remote frames with 11-bit standard
IDs. |
Reject Remote Frames Extended
| Value | Description |
|---|
| 0 |
Filter remote frames with 29-bit extended
IDs. |
| 1 |
Reject all remote frames with 29-bit extended