Voltage References System (VREF) Control
Name:
VREF
Offset:
0x1C
Reset:
0x00000000
Access:
PAC Write-Protection
Bit3130292827262524
Access
Reset
Bit2322212019181716
SEL[3:0]
AccessR/WR/WR/WR/W
Reset0000
Bit15141312111098
Access
Reset
Bit76543210
ONDEMANDRUNSTDBYVREFOETSEN
AccessR/WR/WR/WR/W
Reset0000

Bits 19:16 – SEL[3:0]: Voltage Reference Selection

Voltage Reference Selection

These bits select the Voltage Reference for the ADC / SDADC/ DAC.

ValueDescription
0x0 1.024V voltage reference typical value.
0x2 2.048V voltage reference typical value.
0x3 4.096V voltage reference typical value.
Others Reserved

Bit 7 – ONDEMAND: On Demand Control

On Demand Control

The On Demand operation mode allows to enable or disable the voltage reference depending on peripheral requests.

ValueDescription
0 The voltage reference is always on, if enabled.
1 The voltage reference is enabled when a peripheral is requesting it. The voltage reference is disabled if no peripheral is requesting it.

Bit 6 – RUNSTDBY: Run In Standby

Run In Standby

The bit controls how the voltage reference behaves during standby sleep mode.

ValueDescription
0 The voltage reference is halted during standby sleep mode.
1 The voltage reference is not stopped in standby sleep mode. If VREF.ONDEMAND=1, the voltage reference will be running when a peripheral is requesting it. If VREF.ONDEMAND=0, the voltage reference will always be running in standby sleep mode.

Bit 2 – VREFOE: Voltage Reference Output Enable

Voltage Reference Output Enable

ValueDescription
0 The Voltage Reference output is not available as an ADC input channel.
1 The Voltage Reference output is routed to an ADC input channel.

Bit 1 – TSEN: Temperature Sensor Enable

Temperature Sensor Enable

ValueDescription
0 Temperature Sensor is disabled.
1 Temperature Sensor is enabled and routed to an ADC input channel.