Configuration A
Name:
CFGA
Offset:
0x02
Reset:
0x0000
Access:
PAC Write-Protection, Enable-protected
Bit15141312111098
Access
Reset
Bit76543210
REFNUM[7:0]
AccessR/WR/WR/WR/WR/WR/WR/WR/W
Reset00000000

Bits 7:0 – REFNUM[7:0]: Number of Reference Clock Cycles

Number of Reference Clock Cycles

Selects the duration of a measurement in number of CLK_FREQM_REF cycles. This must be a non-zero value, i.e. 0x01 (one cycle) to 0xFF (255 cycles).