The RTC can generate the following output events:
- Overflow (OVF): Generated when the
counter has reached its top value and wrapped to zero.
- Compare (CMPn): Indicates a match
between the counter value and the compare register.
- Alarm (ALARM): Indicates a match between the clock value and the alarm register.
- Period n (PERn): The corresponding bit
in the prescaler has toggled. Refer to Periodic Intervals for details.
Setting the Event Output bit in the Event
Control Register (EVCTRL.xxxEO=1) enables the corresponding output event. Writing a zero to
this bit disables the corresponding output event. Refer to the EVSYS - Event System for
details on configuring the event system.