Wake-Up Time

Conditions:

CPU sets an IO by writing PORT->IOBUS without jumping in an interrupt handler (Cortex M0+ register PRIMASK=1). The wakeup time is measured between the edge of the wakeup input signal and the edge of the GPIO pin.

Table 1. Wake-up Timings
Sleep Mode Typ Unit
IDLE 15.2 µs
STANDBY 48 µs