Due to asynchronicity between the main clock
domain and the peripheral clock domains, some registers need to be synchronized when
written or read.
The following bits are synchronized when written:
- Software Reset and Enable bits in Control A register (CTRLA.SWRST and
CTRLA.ENABLE)
- Capture Channel Buffer Valid bit in STATUS register (STATUS.CCBUFVx)
The following registers are
synchronized when written:
- Control B Clear and Control B Set registers (CTRLBCLR and CTRLBSET)
- Count Value register (COUNT)
- Period Value and Period Buffer Value
registers (PER and PERBUF)
- Channel x Compare/Capture Value and
Channel x Compare/Capture Buffer Value registers (CCx and CCBUFx)
The following registers are
synchronized when read:
- Count Value register (COUNT): synchronization is done on demand through READSYNC
command (CTRLBSET.CMD).
Required write-synchronization
is denoted by the "Write-Synchronized" property in the register description.
Required
read-synchronization is denoted by the "Read-Synchronized" property in the register
description.