Counter Value
Note: Prior to any read access, this register must be synchronized by user by writing the according TCC Command value to the Control B Set register (CTRLBSET.CMD=READSYNC).
Name:
COUNT
Offset:
0x34
Reset:
0x00000000
Access:
PAC Write-Protection, Write-Synchronized, Read-Synchronized
Bit3130292827262524
Access
Reset
Bit2322212019181716
COUNT[23:16]
AccessR/WR/WR/WR/WR/WR/WR/WR/W
Reset00000000
Bit15141312111098
COUNT[15:8]
AccessR/WR/WR/WR/WR/WR/WR/WR/W
Reset00000000
Bit76543210
COUNT[7:0]
AccessR/WR/WR/WR/WR/WR/WR/WR/W
Reset00000000

Bits 23:0 – COUNT[23:0]: Counter Value

Counter Value

These bits hold the value of the counter register.

Note: When the TCC is configured as 16-bit timer/counter, the excess bits are read zero.
Note: This bit field occupies the MSB of the register, [23:m]. m is dependent on the Resolution bit in the Control A register (CTRLA.RESOLUTION):
CTRLA.RESOLUTION Bits [23:m]
0x0 - NONE 23:0 (depicted)
0x1 - DITH4 23:4
0x2 - DITH5 23:5
0x3 - DITH6 23:6