OSCCON3
0, the user may not see this bit set (NOSCR =
1). When the oscillator becomes ready, there may be a
delay of one instruction cycle before NOSCR is set. The clock switch occurs
in the next instruction cycle and NOSCR is cleared.| Bit7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| CSWHOLD | SOSCPWR | ORDY | NOSCR | ||||
| AccessR/W/HC | R/W | R | R | ||||
| Reset0 | 1 | 0 | 0 |
Clock Switch Hold Control
| Value | Description |
|---|---|
| 1 | Clock switch (and interrupt) will hold when the oscillator selected by NOSC is ready |
| 0 | Clock switch will proceed when the oscillator selected by NOSC is ready |
Secondary Oscillator Power Mode Select
| Value | Description |
|---|---|
| 1 | Secondary Oscillator operates in High-Power mode |
| 0 | Secondary Oscillator operates in Low-Power mode |
Oscillator Ready (read-only)
| Value | Description |
|---|---|
| 1 | OSCCON1 = OSCCON2; the current system clock is the clock specified by NOSC |
| 0 | A clock switch is in progress |